- key - ribasimVersion : the ribasim version used; versions 6 and 7 supported
- key - tmsUnit : the base unit to use by RIBASIM; 1 = m3/s, 2 = mm/day, 3 = mm/tms, 4 = ppt (when not specified, the default is m3/s)
- key - tmsHeader : the full path of a custom TMS file header to use by the pre-adapter (optional)
- key - simulationTimestep : the RIBASIM time step to use, supported are DAY, MONTH, HALFMONTH, DECADE, WEEK
- key - stateExportDir : the directory where FEWS exports and imports the RIBASIM state file (when not specified, the folder containing the InputStateDescriptionFile is used)
- key - stateFile : the filename of the statefile used by RIBASIM (when not specified it will have the same name as given in the InputStateDescriptionFile)
- key - runsimpFile : the full path of the control file for RIBASIM (when not specified, runsimp.dat will be created in the working folder)
- key - runsimpTemplate : the full path of the control file template (when not specified, no "runsimp" control file will be created)
- key - orderByQualifier : when true, the input time series can be provided with a qualifier (integer) per location to set both the order and header of the columns in the generated TMS file.
...