Current Release: Wanda 4.7

Wanda 3.72

Deltares is pleased to announce the availability of Wanda 34.72. This version is the second official release in the 3.7 series and improves the stability and existing functionality of Wanda 3.77 This release resolves several issues that have been discovered since the release of Wanda 4.6 and introduces new functionality and improvements. For a complete list of new features and known problems, please see the Release Notes and Errata list below.

Wanda

3.72 Release notes

What's new in WANDA 3.72

Wanda 3.72 is primarily a bugfix release and includes all changes since Wanda 3.71 (released 23 March 2009).

Wanda 3.72 includes the following new features and improvements:

  • Windows 7 and 64-bit versions of Windows XP/Vista are now fully supported
  • WEC (Wanda External Communication) module improved and New WECDAQ44 control component for PLC commissioning (licensed customers only)
  • Wiki Markup
    *\[WANDA-106\]* Improved file saving; Wanda only asks to save the case if something has been changed.
  • Wiki Markup
    *\[WANDA-107\]* Wanda correctly handles read-only files.
  • Wiki Markup
    *\[WANDA-116\]* Control valve (FCV, PuCV, PdCV) test added: recommended dt < Tclosure

Wanda 3.72 fixes the following issues

  • Wiki Markup
    *\[WANDA-2\]* Resizing action table crashes the user interface.
  • Wiki Markup
    *\[WANDA-5\]* Sensor properties are not converted correctly when opening a Wanda 3.70 case.
  • Wiki Markup
    *\[WANDA-14\]* The component-specific output property "Air pressure" of the Vertical non-vented air vessel is incorrectly adjusted for the atmospheric pressure (only in steady calculation).
  • Wiki Markup
    *\[WANDA-15\]* The component-specific output property "Gas pressure" of the Damper/surge vessel is incorrectly adjusted for the atmospheric pressure (only in unsteady calculations).
  • Wiki Markup
    *\[WANDA-16\]* PIDSS and PIDSS_N don't switch on/off properly under special circumstances.
  • Wiki Markup
    *\[WANDA-95\]* V-notch weir improved (in previous versions Initial state Dry could not be changed to Critical during simulation)
  • Wiki Markup
    *\[WANDA-102\]* Invalid Chart window sizes/coordinates in templates.ini file (chart window doesn't show) under some circumstances.
  • Wiki Markup
    *\[WANDA-108\]* Pressure ratio is not calculated in steady states for control valves (FCV, PuCV, PdCV) if initial state is other than 'position'.
  • Wiki Markup
    *\[WANDA-118\]* After starting Wanda, only flowcharter window comes up (problem with Windows Registry permissions).
  • Fixed the shape definition of the Vent inflow/outflow char.; resulted in a crash under some circumstances.

Known issues in Wanda 3.72:

  • Wiki Markup
    *\[WANDA-103\]* Changing the selected components will reset the layout of graphs to default.

The Release announcement contains information on how to obtain Wanda 3.72

Errata

No patches have been released for Wanda 3.72

4 Errata

Known issues

  • Free surface pipe - For small diameter pipes the fixed lower limit of the Preismann slot (2 mm) can lead to loss of discharge. (WANDA-2690)

Release notes

2024-10-17 - Wanda 4.7

This release addresses/fixes the following issues:

  • Added new feature to the Check valve component. The user can set the initial state of the check valve to automatic. WANDA determines the initial (i.e., open or closed) state in the steady-state calculation.
  • Fixed the error message for the Pump component when the efficiency is greater than100%
  • Extended Pump model. It has a new drive type: Discharge. This allows for prescribing the discharge of the pump over time by means of an action table or a signal line from a control loop. The pump speed is in this case a dependent variable.
  • Added new feature for the Control valve component (): It is possible now to define an initial zero flow. The valve position will be determined on basis of the hydraulic solution, which means that it will be closed if the initial discharge through the valve is zero.
  • Added the Flow (Froude) number at time t = 0 as a new output property to the Pipe component.
  • Added warning for the Valve component. WANDA gives a warning to the user when the steady state valve position is different from the first value in the action table.
  • Fixed the behaviour of the Filling pipe section with airvalve component.
  • Fixed crashes Dynamic check valve component due to repeated open and closing of the valve in a time step.
  • Fixed that the table values (height - area) for a reservoir no longer allows surface area values of zero.

Full release notes: ReleaseNotes Wanda 4.7.0

2020-02-05 - Wanda 4.6

This release addresses/fixes the following issues:

  • Fixed issue where Wanda would crash on startup due to a Windows update (WANDA-3362)
  • Improved setup process, now using Windows installer (MSI) (WANDA-377, WANDA-3264)
  • New matrix solver and numerical improvements, results in significant performance gains for Wanda models with multiple pipe components or many pipe elements.
  • Speed improvement in pipe by more efficiently calculating of the friction factor.
  • Improvements to T- and Y-junction components, results in more stable behaviour in steady state and significant performance improvement.
  • Bug fix to T- and Y-junction components. Cavitation around a T- or Y-junction could result in a singular matrix. This is solved.
  • Stability improvements for the Free surface conduit
  • Updated user interface to the latest version of iGrafx Flowcharter (WANDA-3410, WANDA-3347, WANDA-3340)
  • Fixed case conversion issue with older models, Pipe profile of pipe invert was not converted to centreline (WANDA-3418)
  • Fixed issue with VENT component, where an incorrect initial state would result in a singular matrix without error message (WANDA-3354)
  • 2COND control component behaviour was incorrect, not in line with manual (WANDA-394).

Full release notes: ReleaseNotes Wanda 4.6.0


2019-09-4 - Wanda 4.5.5

This release addresses/fixes the following issues:

  • Fix "Invalid procedure call or argument 5 0" error when starting Wanda after installing August 2019 Windows 10 updates (WANDA-3362)

2018-07-19 - Wanda 4.5.4

This release addresses/fixes the following issues:

  • Fix incorrect interpretation of the Heat capacity Cp in Wanda Heat module (WANDA-3139)

2018-02-16 - Wanda 4.5.3

This release addresses/fixes the following issues:

  • Fix "Overflow 6 0" error when starting Wanda on Windows 10 Fall Creators Update (1709)
  • Fix slurry fluid friction calculation in transition region between laminar and turbulent
  • Many small fixes for Wanda Heat

2017-02-21 - Wanda 4.5.2

This release addresses/fixes the following issues:

  •     Possible crash in vent and some other components due to undefined behavior (rel. WANDA-2865)
  •     Fluid window pops up instead of running simulation. (WANDA-2864)
  •     Calculating system characteristics fails with "case invalid" message. (WANDA-2873)
  •     Fix 'IO error during file copy. Contact Deltares' when running simulation.
  •     Fix accumulation of small temperature increments in heat pipe (WANDA-2861)

2017-02-09 - Wanda 4.5.1 (first public 4.5 release)

This release addresses/fixes the following issues:

  • WANDA no longer relies on the presence of short filenames. (a.o. WANDA-2069, WANDA-2102, WANDA-2851)
  • Write performance is improved. This is most noticeable when running simulations on network storage.
  • Stability improvements to the Y-junction, vent2leg, and the fast filling pipe.
  • Many UI fixes (WANDA-291, WANDA-409, WANDA-877, WANDA-2375, WANDA-2406, WANDA-2432, WANDA-2651, WANDA-2714, WANDA-2799, WANDA-2842, WANDA-2844)
  • Many small bug fixes to the WANDA core.

2016-10-20 - Wanda 4.4.3

This release addresses/fixes the following issues:

  • Possible user interface error on Windows 8.1 and Windows 10 platforms (WANDA-2744, WANDA-2756, WANDA 2765, WANDA-2768)
  • User interface error (like above) on Epanet import fixed (see WANDA-2760)
  • Unphysical results in merger component in steady state (WANDA-2770)
  • Doubly written data in resume mode. This did not affect simulation results (WANDA-2764)

2016-07-29 - Wanda 4.4.2

Fix possible user interface error when upgrading to Wanda 4.4 ("Can not load Wanda plugin", see also WANDA-2702).

2016-06-30 - Wanda 4.4.1

The release notes for Wanda 4.4.1 release are available via the Download page